Phasetronics EZ3 SCR Power Controller Operation and Service Manual
This manual provides detailed instructions for operating and servicing Phasetronics EZ3 SCR power controllers, covering manual and automatic control setups, wiring, specifications, and start-up procedures. It includes information on mounting, power connections, jumper settings, and replacement parts for various amp ratings. The manual also addresses safety precautions and warranty terms.
Read onlinePhasetronics EZ3 specifications
| Output Voltage | 0 to 100% |
|---|---|
| AC Supply Voltage | 120/208/240/380/415/480/575 Vac (+10% to -15%, 50/60 Hz) |
| Ambient Temperature | 0 to 40 degrees C (32 degrees F to 104 deg. F) |
| SCR Peak Inverse Voltage (PIV Rating) | 1600V for units up to 100A, 1800V for units 150A to 1000A |
| Cooling | Convection cooling through 150A. Fan cooled at 225A and above. |
Source: Phasetronics EZ3 SCR Power Controller Operation and Service Manual
All Phasetronics EZ3 documents by type
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
What is the output voltage range of the EZ3 controller?
The output voltage range is 0 to 100%.
From: Phasetronics EZ3 SCR Power Controller Operation and Service Manual
What are the supported AC supply voltages?
Supported AC supply voltages are 120/208/240/380/415/480/575 Vac (+10% to -15%, 50/60 Hz).
From: Phasetronics EZ3 SCR Power Controller Operation and Service Manual
What is the maximum current rating for the EZ3 Series?
The EZ3 Series supports current ratings from 10A to 1000A.
From: Phasetronics EZ3 Series SCR Power Controller Service Manual
What types of loads can the EZ3 Series control?
The EZ3 Series is designed for resistive loads only.