Phasetronics EP1 Series Single-Phase SCR Power Controller Operation & Service Manual

This manual describes the specifications, features, installation, connections and startup of the Phasetronics EP1 series single-phase SCR power controllers.


Phasetronics EP1 Series Single-Phase SCR Power Controller Operation & Service Manual - cover page
Brand
Phasetronics
Document type
Service Manual
Language
English
Pages
26
File format
PDF
File size
1.1 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
F5DB5C3B3BEBA4B58D07A508924BC8FD

About this manual

This service manual provides detailed instructions for installing, connecting, and operating the Phasetronics 4J OHM single-phase SCR power controller. It covers specifications, mounting, ventilation, power and control connections, optional features, startup procedures, and troubleshooting steps including SCR testing and board replacement. The controller supports 120–575VAC and 10–1000A current ratings, with options for soft start, current limit, and voltage regulation. Safety warnings are included for handling live voltage.

The manual includes diagrams for main logic boards and option boards, as well as tables for dimensions and protective networks. It also specifies cooling requirements based on current rating and ambient temperature, and provides guidelines for enclosure ventilation and cleaning to ensure proper operation and longevity.

What's inside

  • Introduction
  • Specifications
  • Installation
  • Connections
  • Options
  • Start-Up
  • Diagrams
  • Troubleshooting
  • Warranty Information

Specifications

Output Current Rating10 to 1000 Amps
AC Supply Voltage120/208/240/380/415/480/575 Vac (+10% to -15%, 50/60 Hz)
Ambient Temperature Operating Range0°C to 40°C (32°F to 104°F)
Cooling MethodConvection cooled (10–150A), Fan cooled (225A and above)
Input Impedance (4-20mA)250 ohms
Input Impedance (0-10Vdc)100k ohms
SCR Peak Inverse Voltage (PIV Rating)1500V (minimum)

Frequently asked questions

What is the operating temperature range for the EP1 series?

The operating temperature range is 0°C to 40°C (32°F to 104°F).

How is the EP1 series cooled?

Units rated 10 to 150A are convection cooled; units rated 225A and above are fan cooled.

What are the input options for control signals?

The unit supports 4-20mA, 0-5Vdc, and 0-10Vdc analog inputs, plus manual control via a 10k ohm potentiometer.