This document is an introduction to the AirWorks AWK-3131A user manual
The AWK-3131A is an 802.11n compliant wireless access point designed for harsh industrial environments, supporting temperatures from -40°C to 75°C. It features DIN-rail mounting, IP30 housing, and dual-band (2.4/5 GHz) wireless connectivity. The manual covers installation, web console configuration, firmware upgrades, and troubleshooting.
Key features include advanced wireless security (WEP/WPA2), STP/RSTP for network redundancy, Turbo Roaming, AeroLink Protection, and RS-232 console management. LED indicators and a beeper provide real-time status feedback, while a relay output supports event-triggered alerts.
| Wireless Standard | IEEE 802.11a/b/g/n |
|---|---|
| Operating Temperature | -40 to 75°C (wide temperature model) |
| Power Input | 12 to 48 VDC or IEEE 802.3af Power over Ethernet |
| Mounting | DIN-Rail or wall mounting |
| Housing Rating | IP30 |
The standard model operates from -25°C to 60°C, while the wide temperature model operates from -40°C to 75°C.
Hold the RESET button for over 5 seconds until the STATE LED starts blinking green, then release.
It indicates system failures or user-configured events. Blinking fast (0.5s) means it cannot get an IP address from DHCP.
It supports redundant wireless communication for network reliability.