The EG2000 controller is an electronic governor controller that controls generator smoke and idling.
This manual provides step-by-step instructions for installing and operating the EG2000 electronic governor controller. It details electrical connections, adjustment of idle speed, ramp time, droop, gain, and integration. The controller works with magnetic pickups and actuators to regulate engine RPM based on load and speed settings. It supports both isochronous and non-isochronous operation modes and includes remote speed control via potentiometers.
| Operating Voltage | 12 / 24 Vdc +/- 20% |
|---|---|
| Output Current | 0.5-15A |
| Run Speed Adjustment Range | 4 Segment DIP Switch Adjustment From 600 — 9500 Hz |
| IDLE Speed Adjustment Range | Run Speed 30 - 85% |
| Ramp Time | 3- 20 Sec |
| Run Speed Stability | Less than +/- 0.25% |
| MPU Input Signal | 1-120 Vac RMS |
| Dimensions | 147.0 (L) x 114.0 (W) x 50.0 (H) mm |
| Weight | 690 g +/- 2% |
| Operation Temperature | -40 to +85 °C |
| Storage Temperature | -40 to +85 °C |
| Relative Humidity | Max. 95% |
| Vibration | 1.0G @ 18-30 Hz, 2.5 Gs @ 48 — 70 Hz |
12 / 24 Vdc +/- 20%.
3 to 20 seconds.
1-120 Vac RMS.