The EA63-4 type automatic voltage regulator is compatible with Basler AVC63-4A, with a maximum output voltage of 63Vdc, a power input of 95-139Vac +/-10%, and a frequency of 50/60Hz, which can be selected.


Kutai EA63-4 Generator Automatic Voltage Regulator Operation Manual - cover page
Brand
Kutai Electronics Industry Co., Ltd.
Category
Generator
Document type
User Manual
Language
English
Pages
5
File format
PDF
File size
474 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
A735C35D51A999CDDCFE8BA9EB21B1FF

About this manual

This document provides detailed instructions for operating and adjusting the Kutai EA63-4 generator automatic voltage regulator. It includes sections on specifications, operation procedures, and system startup. The manual covers voltage regulation, frequency compensation, overexcitation shutdown, and stability adjustment. It also includes diagrams for wiring and testing setups, along with safety warnings and troubleshooting guidance.

The regulator is designed for self-excited applications and is compatible with Basler AVC63-4A. It features adjustable frequency compensation, voltage regulation, and overexcitation protection. The manual includes technical specifications such as voltage input range, frequency response, and environmental operating conditions.

What's inside

  • SECTION 1 : SPECIFICATION
  • SECTION 2 : OPERATION PROCEDURE
  • 2.1 Stability Adjust Rheostat (STAB)
  • 2.2 Operation
  • 2.3 Preliminary Set-Up
  • 2.4 System Star-Up
  • 2.5 Operational Test
  • Interconnection Diagrams
  • Safety Warnings
  • Troubleshooting

Specifications

Frequency50 / 60 Hz, selectable
Static Power DissipationMax.15 watts
Excitation Output CurrentContinuous 4A, Intermittent 7A for 60 secs. 9A for 10 secs.
Voltage Thermal Drift ResistanceMin. 15 ohm Max. 100 ohm Less than 3% at temperature range -40 to +70 ˚C
Operating Temperature-40 to +60 ˚C
Storage Temperature-40 to +85 ˚C
Relative HumidityMax. 95%
Dimensions140.0 (L) x 125.0 (W) x 48.0 (H) mm
Weight280 g +/- 2%
Over Excitation Shutdown VoltageMax. 63 Vdc
Fuse SpecSlow blow 5 x 20mm S505-6.3A / 250V

Frequently asked questions

How do I adjust the corner frequency for 50 Hz or 60 Hz systems?

For 60 Hz systems, the regulator is preset at 55 Hz. For 50 Hz systems, connect a jumper across terminals Hz 1 and Hz 2. The corner frequency can be adjusted using the U/F ADJ rheostat.

How do I reset the AVR after overexcitation shutdown?

Decrease the input voltage to less than 6 Vac for a minimum of 2 seconds, which can be done by stopping the prime mover or interrupting the regulator input with a reset switch.

What is the voltage regulation accuracy under load?

Voltage regulation should be better than +/- 1.0% no-load to full-load.