Itron 100G Datalogging Installation Guide - Direct Mount 07/28/2010 TDC-0823-005 Installation Guide

This document is the manual for Itron 100G Datalogging Installation Guide - Direct Mount 07/28/2010 TDC-0823-005, which mainly covers the wiring, installation and operation methods of the device


Itron 100G Datalogging Installation Guide - Direct Mount 07/28/2010 TDC-0823-005 Installation Guide - cover page
Brand
iTRON
Category
Other Electronics
Document type
Installation Guide
Language
English
Pages
32
File format
PDF
File size
2.5 MB
Published
19 October, 2023
Updated
19 October, 2023
Model
100G
MD5 checksum
AF95BF6397E7393ECF8C7F2FB56D4BF7

About this manual

This document serves as an installation guide for the Itron 100G Datalogging gas endpoint, a radio-frequency device designed to transmit meter data. It provides step-by-step instructions for installing the endpoint on a wide variety of gas meters, including models from Elster American, Sensus/Rockwell, Itron/Sprague, National/Lancaster, Dresser ROOTS, and Itron Actaris commercial meters. The guide covers both standard 100G endpoints and the 100G Datalogging version, noting that mechanical installation procedures are identical for both.

What's inside

  • Transmission Modes
  • Specifications
  • Meter Compatibility List
  • Installation Prerequisites
  • Elster American Meter Installation
  • Sensus/Rockwell Meter Installation
  • Itron/Sprague Meter Installation
  • National/Lancaster Meter Installation
  • Commercial Meter Installation
  • Dresser ROOTS Commercial Rotary Meter Installation

Specifications

Tamper DetectionTilt tamper and magnetic tamper
Operating Temperatures-40° to 158° F (-40° to +70° C)
Operating Humidity5 to 95 percent relative humidity
Program Frequency908 MHz
Transmit Frequency908 to 924 MHz
Fixed Network Mode Output Power250 milliwatts or +24 dBm
Mobile and Handheld Mode Output Power10 milliwatts or +10dBm

Frequently asked questions

What is the expected battery life in Fixed Network Mode?

The expected battery life is 20 years.

What is the expected battery life in Mobile and Handheld Mode?

The expected battery life is 20 years.

Can the 100G Datalogging gas endpoint be modified by the user?

No, the device and antenna shall not be changed or modified without the expressed approval of Itron.

Is an FCC license required to read the 100G Datalogging gas endpoint?

No, an FCC license is not required.

Download PDF (2.5 MB)