This document is the owner's manual of Lippert Above Floor Slide-out System, which introduces the function and use method of the product
This manual provides instructions for operating the Lippert Above Floor Slide-out System, including extending and retracting the slide-out room. It also covers preventative and mechanical maintenance, troubleshooting common issues, and manual override procedures. Safety warnings are emphasized to prevent injury or damage during operation.
The system uses a rack and pinion mechanism with a bi-directional electric motor and automatic braking. Maintenance is minimal, with no lubrication required, and electrical issues are typically due to poor ground connections or damaged wiring.
Reverse the motor wires on the back of the switch. Wire size must be 10ga. min.
Check for and clear obstruction or check battery voltage, blown fuse, defective wiring.
The gear key is broken or lost. Replace gear drive assembly.
Teeth on gear drive broken or worn. Replace gear drive assembly.