Lippert F.A.S.T. Track Slide-Out Service Manual

Service manual for the Lippert F.A.S.T. Track slide-out system, covering operation, programming, troubleshooting, and repair instructions.


Lippert F.A.S.T. Track Slide-Out Service Manual - cover page
Brand
Lippert
Category
Vehicle maintenance
Document type
Service Manual
Language
English
Pages
20
File format
PDF
File size
6.7 MB
Published
15 October, 2026
Updated
15 October, 2026
MD5 checksum
A56B9FD5CA45B0A51105DD608B1F8D08

About this manual

This document is a service manual for the Lippert F.A.S.T. Track Slide-Out system, a cable-driven mechanism operated by a 12V DC electric motor. The system is designed to actuate rooms up to 2,000 lbs and 40 inches of stroke. It includes information on major components, safety procedures, and operation instructions for extending and retracting the room.

What's inside

  • System Information
  • Major Components
  • Safety Information
  • Prior to Operation
  • Operation
  • Programming
  • Troubleshooting
  • Fault Codes
  • Service Instructions
  • Motor Replacement

Specifications

Actuation Weightup to 2,000 lbs
Stroke Length40 inches
Motor Voltage12V DC
Motor TypeGear motor

Frequently asked questions

What is the minimum voltage required for the slide-out to move?

The room will not move if the voltage is 10.5V DC or below.

What should be done if the parking brake is not set?

Set the parking brake (if applicable) and check for continuity to ground on the wire plugged into the parking brake receptacle.

How do you set the retract stop point?

Press and hold the "IN" or "RET" button, move the room to the fully retracted position, and hold the button for 2 seconds after it stops.