This is a product manual that describes the use and characteristics of the Pressure Sensor PS600.
This manual provides instructions for installing, maintaining, and troubleshooting the Greenspan PS600 pressure sensor. It includes details on sensor design, connection methods, field deployment, and warranty terms. The sensor is a two-wire device with a ceramic capacitive transducer, designed for robust performance in water depth measurement applications. It features high overload protection and is calibrated for use with water or seawater, with corrections for gravity and density. The manual also covers venting systems and optional accessories like the CVS-001 air drying system for vented sensors.
Warranty information states that all new Greenspan products are covered for 12 months against defects in materials and workmanship, provided they are not altered or repaired outside authorized service centers. The sensor’s output is a 4–20mA current signal, and it requires a supply voltage of 8–30VDC. Technical support is available via phone at +61 7 4660 1888.
| Output Signal | 4–20mA current |
|---|---|
| Supply Voltage | 8–30VDC |
| Overpressure Rating | Up to 60 times nominal pressure |
| Cable Resistance | 9 ohms per 100m |
All new Greenspan products are warranted against defects in materials and workmanship for 12 months from the date of invoice.
The warranty will be voided if the product is altered or repaired outside of the Greenspan factory or other authorized service centre.
The sensor outputs a 4–20mA current signal, corresponding to 0 to full-scale pressure.
The sensor requires a supply voltage between 8–30VDC.