geosquirt™ 12 VDC Purge Pump is a device used to remove liquid contamination. It can be used for water and other liquids. It can work continuously for 15 minutes and then needs to cool for 5 minutes.
This manual provides step-by-step instructions for installing and operating the Geotech geosquirt™ 12 VDC Purge Pump. It includes safety warnings, operational limits, and cooling requirements. The pump is designed for water-only use and must be submerged. It is disposable with no repair parts, and troubleshooting covers power and flow issues. Maintenance involves cleaning with a three-bucket wash between uses.
| Dimensions | 1.5" diameter x 13" length (4 cm diameter x 33 cm length) |
|---|---|
| Outlet Required | 3/8" (10 mm) I.D. tubing |
| Power Requirement | Independent 12 VDC source |
| Current Draw | 3.5 amps (Single), 7.0 amps (Dual) |
| Operating Temperature | In water up to 60°C (140°F) do not freeze pump |
| Flow Rate | Up to 2.5 GPM (11 LPM) |
| Maximum Recommended Depth | 55 feet (17 m) |
| Material of Casing | ABS plastic |
| Material of Pump Impeller | Stainless steel |
| Material of Seal | Rubber |
| Length of Motor Lead | 30 feet, 60 feet (9 m,18 m) |
No, pumping silt or sand will destroy the pump and void any warranty.
Thirty (30) days from date of first sale, covering defects in materials and workmanship.
Check power connectors, power supply voltage, and motor lead for kinks or breaks.
Pump for up to 15 minutes, then cool for 5 minutes before resuming.