Key facts
- Brand
- Geotech
- Model
- geosquirt™ 12 VDC Purge Pump
- Documents
- 2
- Languages
- EN
- Last added
- 2023-10-18
Start here

Geotech geosquirt™ 12 VDC Purge Pump User Manual
This manual provides step-by-step instructions for installing and operating the Geotech geosquirt™ 12 VDC Purge Pump. It includes safety warnings, operational limits, and cooling requirements. The pump is designed for water-only use and must be submerged. It is disposable with no repair parts, and troubleshooting covers power and flow issues. Maintenance involves cleaning with a three-bucket wash between uses.
Read onlineGeotech geosquirt™ 12 VDC Purge Pump specifications
| Dimensions | 1.5" diameter x 13" length (4 cm diameter x 33 cm length) |
|---|---|
| Outlet Required | 3/8" (10 mm) I.D. tubing |
| Power Requirement | Independent 12 VDC source |
| Current Draw | 3.5 amps (Single), 7.0 amps (Dual) |
| Operating Temperature | In water up to 60°C (140°F) do not freeze pump |
| Flow Rate | Up to 2.5 GPM (11 LPM) |
| Maximum Recommended Depth | 55 feet (17 m) |
| Material of Casing | ABS plastic |
| Material of Pump Impeller | Stainless steel |
| Material of Seal | Rubber |
| Length of Motor Lead | 30 feet, 60 feet (9 m,18 m) |
All Geotech geosquirt™ 12 VDC Purge Pump documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Can the geosquirt™ pump silt or sand?
No, pumping silt or sand will destroy the pump and void any warranty.
What is the warranty period?
Thirty (30) days from date of first sale, covering defects in materials and workmanship.
Can the geosquirt pump silt or sand?
No, pumping silt or sand will destroy the pump and void any warranty responsibility on the part of Geotech Environmental Equipment.
What is the warranty period for the geosquirt?
The product is warranted for 30 days from the date of first sale against defects in materials and workmanship.