The Geotech Plume Eater® is an in-situ remediation system designed to remove volatile organic contaminants from groundwater using air injection and microbial enhancement. It operates by lifting groundwater within a well structure, removing VOCs, and re-injecting treated, oxygenated water back into the subsurface. The system is available in 2-inch and 4-inch versions, with components including flexible PVC tubing, air supply lines, packer assemblies, and optional filters. Installation involves deploying the unit into a well, inflating the packer, and connecting air lines to maintain flow.

The manual provides detailed instructions for setup, operation, maintenance, and component specifications, including air pressure and flow requirements, well depth compatibility, and safety precautions for handling compressed air and cleaning procedures. This manual is written in Spanish.

What's inside

  • System Description
  • System Components
  • Installation and Operation
  • System Maintenance
  • Parts List
  • Warranty and Repair

Specifications

Air Pressure Requirement (PSIG)5–35 PSIG (.34-2.4 bar)
Air Flow Requirement (SCFM)1–5 SCFM
Minimum Submersion Depth8 feet (2.4 m)
Maximum Installation Length (2-inch)35 feet (10.7 m)

Frequently asked questions

What is the recommended air pressure for the Plume Eater®?

Adjust the air pressure to at least 5 psi (.34 bar) above the calculated static head pressure to account for hard water and mineral deposits.

What is the recommended air flow rate?

The recommended air flow rate is between 1–5 SCFM for efficient operation.