Geotech AR4 4" Auto-Reclaimer Installation and Operation Manual

This manual describes the function and operation of the 4” Auto-Reclaimer (AR4). It provides detailed information about the system including the system components, installation, operation, maintenance, and troubleshooting.


Geotech AR4 4" Auto-Reclaimer Installation and Operation Manual - cover page
Brand
Geotech
Category
Other
Document type
User Manual
Language
English
Pages
43
File format
PDF
File size
3.7 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
3531C58A104A93E67841FC961FCD0E3B

About this manual

The Geotech AR4 is an automatic, controller-less, positive air-displacement pump designed for recovering fluids from depths of up to 250 feet (76.2 meters). It operates using a regulated standard industrial compressed air source and is available in three lengths: short, long, and extended (Ext). The pump can handle fluids with up to 1/8" diameter suspended particles and operates under both positive and negative pressure environments. It is offered with various intake configurations, including top screen, bottom screen, or flat bottom screens.

The document provides detailed instructions for system installation, including attaching air, vent, and discharge hoses, and lowering the pump into the well. It details system specifications such as physical dimensions, weight, maximum depth, air pressure requirements (10-120 PSI), and fluid compatibility. The manual also includes sections on replacement parts, a maintenance schedule, and troubleshooting guides for common issues.

What's inside

  • System Description
  • System Installation
  • System Schematic
  • Pump Activation Levels
  • Air Consumption
  • System Specifications
  • Replacement Parts
  • System Maintenance
  • System Troubleshooting
  • Warranty

Specifications

Maximum Depth250' (76.2 m)
Air Pressure10 - 120 PSI Max
Air Consumption0.25 - 1.25 SCF/GAL
FluidsLandfill leachate, diesel, gasoline, JP1, JP6, #2 heating oils, BTEX, MTBE
pH Range4-9
Max. Temperature220°F (104°C)
Min. Density0.7 SpG
Pump MaterialsSS316, PVDF, FPM, HDPE

Frequently asked questions

What is the maximum depth the AR4 can recover fluids from?

The AR4 can recover fluids from depths of up to 250 feet (76.2 meters).

What is the required air pressure range for the AR4?

The AR4 requires an air pressure between 10 and 120 PSI (0.7 – 8.5 Kg/cm²).

What types of fluids can the AR4 pump?

The AR4 can pump landfill leachate, diesel, gasoline, JP1, JP6, #2 heating oils, BTEX, and MTBE.