This manual provides guidance on the installation and operation of the High Volume Probe Scavenger.
This manual provides installation, operation, maintenance, and troubleshooting instructions for the Geotech High Volume Probe Scavenger system. It covers components like the product pump, water pump, and optional control panel. The system is designed for automatic recovery of floating hydrocarbons from wells up to 80 feet deep. Installation flexibility allows pump and probe placement at desired heights, with minimum 3 feet of product or water in the well. Optional components include a Water Table Depression Pump (WTDP) for enhanced recovery and a tank full sensor to prevent overflow. The standard setup includes a 1/3 HP gasoline-powered pump, explosion-proof starter box, and flexible discharge hose. Maintenance and safety procedures are also detailed, including decontamination protocols for equipment before return or repair. This manual is written in Spanish.
| Maximum Flow Rate | 12 GPM / 45 LPM |
|---|---|
| Maximum Depth | 80 feet / 24.6 meters |
| Power Supply | 230VAC single-phase |
| Discharge Hose Material | FEP/Acero Inoxidable |
The product is guaranteed for one (1) year from the date of first sale against defects in materials and workmanship.
The system is designed for efficient product recovery at depths up to 80 feet.
The product pump has a capacity of up to 12 gallons per minute.
Geotech recommends a well diameter of at least 10 inches for this configuration.