This manual introduces the installation and operation of Redi-Flo 2® and Geotech variable frequency drive systems. This manual includes system description, system installation, system operation, system maintenance, system troubleshooting and system specifications.
This manual provides step-by-step instructions for installing and operating Geotech's Redi-Flo 2® submersible pump and Variable Frequency Drive systems. It covers system components, installation procedures, operation guidelines, maintenance tasks, and troubleshooting. The systems are designed for groundwater sampling and purging, with precise flow control and protection against electrical faults. The manual includes safety warnings, component specifications, and compatibility details for different voltage inputs and well sizes.
The Redi-Flo 2® pump operates with a variable frequency drive to control flow rates from 8 GPM to 100 ml/min, down to 280’ (85 m) depth. It includes a well seal, Happy Hose!® cable, and is compatible with 2” and 4” wells. Installation requires testing pump rotation, securing connections, and ensuring proper electrical input (115V or 230V). Maintenance includes motor winding and insulation resistance tests, and checking impellers and cables.
| Electrical Input (115V model) | 115V(+/-10%)/1PH/48-62Hz/23A |
|---|
The pump can reach depths down to 280’ (85 m).
The VFD uses either 120V or 230V Single-Phase AC input power source.
The flow rate ranges from 8 GPM (30 LPM) to as little as 100ml ⁄min.
The VFD with cords and case weighs 19.2lbs (8.7kg).