This document introduces the Geotech geosquirt 12 VDC Purge Pump. The Geotech geosquirt 12 VDC Purge Pump is a pump for water treatment. It can be used to remove gas in water and ensure the purity of water. When the pump is used, it needs to be immersed in water and cannot be used in the air. Otherwise, the pump will be damaged. The pump cannot be used to pump silt or sand. Otherwise, it will also damage the pump. The pump should be allowed to cool for 5 minutes every 15 minutes during operation.
This manual provides instructions for installing, operating, and maintaining the Geotech geosquirt 12 VDC Purge Pump. It includes safety warnings, operational limits, and troubleshooting steps. The pump is designed for use with water only and must be submerged during operation. It is a disposable unit with no repair parts available. The manual also lists replacement parts and system specifications, including power requirements and dimensions for single, double, and triple stage models.
| Power Requirement | Independent 12 VDC source |
|---|---|
| Current Draw | 3.3 amps (Single), 7.2 amps (Double), 8.0 amps (Triple) |
| Operating Temperature | In water up to 60°C (140°F) do not freeze pump |
| Flow Rate | Up to 2.5 GPM (9.5 LPM) |
| Maximum Recommended Depth | 30 feet (Single), 60 feet (Double), 90 feet (Triple) |
| Pump Material | ABS plastic |
| Material of Seal | Rubber |
| Length of Motor Lead | 30 feet, 60 feet, 90 feet (9 m,18 m, 27 m) |
No, pumping silt or sand will destroy the pump and void any warranty responsibility on the part of Geotech Environmental Equipment.
The product is warranted for 30 days from the date of first sale against defects in materials and workmanship.
Check power connectors, power supply voltage, and motor lead for kinks, breaks, or splits.
Pump for up to 15 minutes, then cool for 5 minutes, then resume pumping.