This is a Geotech VFD for Redi-Flo2® Installation and Operation Manual, which introduces product usage methods, precautions and warranty information.
The Geotech 11201299 Variable Frequency Drive (VFD) is designed to operate and protect the Redi-Flo2 pump, allowing precise control of discharge flow rates from 8GPM down to 100 milliliters per minute. The system features a robust NEMA 4 enclosure suitable for outdoor duty and includes a torque boost feature to aid startup under severe conditions. It is UL Listed to U.S. and Canadian electrical safety standards and is optimized for use with Redi-Flo2 pumps.
| Flow Rate Control | 8GPM (30 LPM) to 100 milliliters per minute |
|---|---|
| Input Voltage (115V Model) | 115V(+/-10%)/1PH/48-62Hz/23A |
| Input Voltage (230V Model) | 230V(+/-10%)/1PH/48-62Hz/23A |
| Output Power | 1.1kW/400Hz/220V/3PH/5.5A |
| Acceleration Time | 0 to 400Hz, 5 seconds |
| Deceleration Time | 0 to 400Hz, 5 seconds |
| Ambient Temperature | -10 - 40degC (14 - 104degF) |
| Storage Temperature | -40 - 60degC (-40 - 140degF) |
| Maximum Humidity | 95%, non-condensing |
| Dimensions (VFD Only) | 10.12" x 7.40" x 7.34" (26 x 19 x 19cm) |
For generators with voltage regulation, 2000 watts at 115/230VAC is recommended; for those without, 5000 watts is recommended.
When powering down, all knobs should be returned to the positions shown in the 'OFF' position.
No, the Redi-Flo2 pump is not recommended for well development or pumping fluid containing abrasives.
The warranty of the Redi-Flo2 pumps will be void if other than the Geotech VFD is used.