This manual describes the installation and operation of the Geosub 2 controller.
The Geotech Geosub 2 system consists of a fully submersible environmental pump and a Watt Controller designed for ground water sampling. The controller provides safe, conditioned variable DC output power from an AC source, allowing for precise control over water flow rates. It features a programmable user interface, dry run protection, and efficient operation suitable for portable AC generator equipment.
| Input Power (120V Model) | 100-130 Volts AC, 4.2 amps nominal full load |
|---|---|
| Input Power (230V Model) | 200-250 Volts AC, 2.1 amps nominal full load |
| Output Power | Variable 0 to 46 Volts DC at < 300 Watts |
| Operating Temperature | -29 to 38°C |
| Weight | 7.46kg |
| Dimensions | 41cmL x 33cmW x 18cmH |
| Pump Full Load Rating | 2/3 HP |
No, the controller has no field serviceable components and should never be opened by an unqualified person.
No, it is specifically designed for use with Geotech's Geosub 2 Pump ONLY.
The maximum output current is 10 amps.