This manual is a maintenance manual for the 5600SXT water treatment device, which introduces the components, installation, operation, troubleshooting and other contents of the water treatment device
This service manual provides detailed instructions for installing, programming, and maintaining the FLECK 5600SXT downflow water softener. It covers installation requirements, timer features, valve assembly, and troubleshooting. The manual includes diagrams for wiring and flow, as well as step-by-step procedures for startup and regeneration cycles. It also addresses safety and compatibility requirements for electrical and plumbing systems.
A minimum of 20 pounds (1.4 bar) of water pressure is required.
Water pressure is not to exceed 125 psi (8.6 bar).
An uninterrupted alternating current (A/C) supply is required.
Backwash flow rates in excess of 7 gpm (26.5 Lpm) require 3/4 inch (19 mm) drain line.