This manual describes the configuration, installation and maintenance instructions for the Fleck 9000/9100/9500 series water conditioners.
This document is a service manual for the Pentair Fleck 9000, 9100, and 9500 series water conditioners. It provides detailed instructions for equipment configuration, installation, and start-up procedures, including specific requirements for water pressure, electrical facilities, and plumbing codes. The manual details the assembly of various components such as control valves, meter assemblies, and brine valve systems.
| Minimum Water Pressure | 25 pounds (1.7 bar) |
|---|---|
| Maximum Water Pressure | 125 psi (8.6 bar) |
| Maximum Water Temperature | 110°F (43°C) |
| Electrical Supply | 115 volt, 60 Hertz |
| Timer Regeneration Time (1/15 RPM) | 82 minutes |
| Timer Regeneration Time (1/30 RPM) | 164 minutes |
A minimum of 25 pounds (1.7 bar) of water pressure is required for the regeneration valve to operate effectively.
The length of time the unit backwashes is determined by the number of pins in the backwash section of the program wheel; the number of pins multiplied by two equals minutes of backwash.
Dow Corning Silicone Compound is recommended for best results, as petroleum-based lubricants can cause swelling in rubber parts.