Pentair Fleck 9000/9100/9500 Series Water Conditioner Service Manual

This manual describes the configuration, installation and maintenance instructions for the Fleck 9000/9100/9500 series water conditioners.


Pentair Fleck 9000/9100/9500 Series Water Conditioner Service Manual - cover page
Brand
Pentair
Category
Water heater
Document type
Service Manual
Language
English
Pages
52
File format
PDF
File size
3.1 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
F6F9128597608D4999762AC2E89CDCD1

About this manual

This document is a service manual for the Pentair Fleck 9000, 9100, and 9500 series water conditioners. It provides detailed instructions for equipment configuration, installation, and start-up procedures, including specific requirements for water pressure, electrical facilities, and plumbing codes. The manual details the assembly of various components such as control valves, meter assemblies, and brine valve systems.

What's inside

  • Job Specification Sheet
  • Equipment Configuration
  • Installation & Start-Up
  • Control Valve Assembly
  • Brine Valve System
  • Meter Assembly
  • Safety Brine Valve
  • Troubleshooting
  • Wiring Diagrams
  • Control Dimensions

Specifications

Minimum Water Pressure25 pounds (1.7 bar)
Maximum Water Pressure125 psi (8.6 bar)
Maximum Water Temperature110°F (43°C)
Electrical Supply115 volt, 60 Hertz
Timer Regeneration Time (1/15 RPM)82 minutes
Timer Regeneration Time (1/30 RPM)164 minutes

Frequently asked questions

What is the minimum water pressure required for regeneration?

A minimum of 25 pounds (1.7 bar) of water pressure is required for the regeneration valve to operate effectively.

How do you change the length of the backwash time?

The length of time the unit backwashes is determined by the number of pins in the backwash section of the program wheel; the number of pins multiplied by two equals minutes of backwash.

What lubricant is recommended for the control valve?

Dow Corning Silicone Compound is recommended for best results, as petroleum-based lubricants can cause swelling in rubber parts.