Endevco 727 Piezoresistive Drop Test Accelerometers Instruction Manual

This instruction manual provides technical detail for the single-axis accelerometers in wax mount configuration.


Endevco 727 Piezoresistive Drop Test Accelerometers Instruction Manual - cover page
Brand
Endevco
Document type
User Manual
Language
English
Pages
9
File format
PDF
File size
340 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
3925045A1941CC5118300DE8C6C14D52

About this manual

This manual provides instructions for using Endevco’s Model 727 piezoresistive drop-test accelerometers, designed for shock measurements in consumer electronics. It covers handling precautions, mounting procedures, cable handling, and electrical specifications. The accelerometers are undamped and lack mechanical stops to maximize bandwidth and linearity. Users must handle them carefully to avoid damage, especially during unmounted handling. Mounting requires a smooth, clean surface with specific roughness and flatness tolerances. Cable routing and strain relief are critical to prevent damage and signal degradation. Electrical considerations include excitation voltage, signal leads, and cable length effects.

What's inside

  • Handling Precautions
  • Initial Checkout
  • Mounting Surface Preparation and Installation
  • Cable Handling
  • Electrical Considerations

Specifications

Excitation Voltage10.000±0.005 Vdc (max 12 Vdc without damage)
Input/Output Resistance650 Ω ± 300 Ω
Surface Roughness32 micro inches rms or better

Frequently asked questions

What is the recommended excitation voltage for the Model 727 accelerometer?

The drop-test accelerometers are calibrated using an excitation voltage of 10.000±0.005 Vdc, unless otherwise specified at the time of order (the maximum excitation voltage without damage is 12 Vdc).

How should the accelerometer be mounted?

Mount the accelerometer on a smooth, clean surface with a surface roughness of 32 micro inches rms or better and a surface flatness tolerance of 0.0003". Use Aremco CrystalbondTM 509 for mounting up to 60°C.

What should be done if the accelerometer is not working properly?

Perform a resistance test to verify the integrity of the Wheatstone bridge. If resistance measurements are outside the specified tolerance, consult the factory for troubleshooting.