Dresser D800 and D1000 Meter Installation, Operation and Maintenance Manual
This manual provides step-by-step instructions for installing, operating, and maintaining Dresser Series D800 and D1000 diaphragm replacement meters. It covers meter setup, calibration, troubleshooting, and maintenance procedures including lubrication, cleaning, and cartridge replacement. The meters are designed for commercial natural gas applications and feature a compact, oil-free design with rotary positive displacement technology. They offer accurate, non-adjustable measurement and support multiple testing methods including differential pressure and proving with external provers.
The manual also includes sections on firmware upgrades, temperature and flow rate measurement, fault and alarm handling, and logging features. Safety precautions and handling guidelines are provided for installation and maintenance, including warnings about operating temperatures and potential hazards.
Dresser D800 specifications
| Operating Temperature Range | -40°F to 140°F (-40°C to 60°C) |
|---|---|
| RPM Wheel Flow Indication | 0.007407 cf (0.0002098 m3) |
| Recommended Inlet Screen | 60 mesh screen |
Source: Dresser Series D Meter D800 and D1000 Installation Supplement
All Dresser D800 documents by type
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How do I check the meter for free rotation after arrival?
Blow dry air lightly into the meter inlet to verify the free rotation of the impellers.
From: Dresser Series D Meter D800 and D1000 Installation Supplement
What should I do if I encounter serious problems during installation?
Immediately notify your Dresser meter supplier and do not attempt repairs or adjustments.
From: Dresser Series D Meter D800 and D1000 Installation Supplement
What is the maximum operating pressure for the Dresser D800/D1000 meter?
The meter is rated at 25psig maximum allowable operating pressure (MAOP).
From: Dresser D800 and D1000 Meter Installation, Operation and Maintenance Manual
What is the temperature operating range for the meter?
The meter operates between -40°F to +140°F (-40°C to +60°C).
From: Dresser D800 and D1000 Meter Installation, Operation and Maintenance Manual
Can the Series D meters replace existing diaphragm meters?
Yes, they can be mounted directly to existing Class 800 and Class 1000 diaphragm meter sets using common connection dimensions.
From: Dresser Series D Meters Models D800 and D1000 Installation Operation and Maintenance Manual
What is the average start rate of the Series D meters?
The average start rate is 0.30 ACFH, with a shut-off rate of 0.15 ACFH.
From: Dresser Series D Meters Models D800 and D1000 Installation Operation and Maintenance Manual