This is a manual for NEC 80000INS07
This hardware manual was developed by NEC America, Inc. for its customers and service personnel and should be read before installing or programming the system. It is identified as 80000INS07 and dated April 2001.
The manual covers installing the cabinet, PCB installation, installing extensions and trunks, optional equipment, maintenance options and SMDR, and specifications and parts. Installation content includes site requirements, planning for 4-slot and 8-slot main equipment cabinets, removing the cover, mounting the wall bracket, hanging and grounding the cabinet, RFI suppressor assemblies, power supply installation, and U-slot and fixed-slot system configuration.
| Conference Circuits | 32 circuits, dynamically allocated |
|---|---|
| Maximum Parties per Conference | 8 |
| Analog Trunks (CO/PBX Lines) | 4 Slot Fixed: 16; 4 Slot U: 24; 8 Slot U: 48 |
| Digital and/or Analog Telephones | 4 Slot Fixed: 32; 4 Slot U: 40; 8 Slot U: 96 |
| Power Supply Input | 120 VAC ±10%, 50-60 Hz |
| Output Power | 91 W at 100% full load |
| Input Current | 1.50 A at 110 V |
| Grounding Requirements | 12 AWG copper wire |
| Environmental Temperature | 0-45°C (32-113°F) |
| Environmental Humidity | 10-95%, non-condensing |
A test set, a punch down tool and a digital voltmeter are listed as tools to have on hand.
A dedicated 110 VAC 60 Hz circuit within seven feet of the cabinet.
Up to 8 parties per conference.
0-45°C (32-113°F).