Schneider Electric ALTIVAR 28 Adjustable Speed Drive Controllers User's Guide

Instruction manual for variable frequency drive, including installation, debugging, maintenance, and maintenance


Schneider Electric ALTIVAR 28 Adjustable Speed Drive Controllers User's Guide - cover page
Brand
Schneider Electric
Category
Motor
Document type
User Manual
Language
English
Pages
87
File format
PDF
File size
887 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
BE98E1407CADAFE51E1BFA98839BECAB

About this manual

This manual provides instructions for the ALTIVAR 28 (ATV28) family of adjustable frequency AC drive controllers, which are used to control three-phase asynchronous motors. The document covers technical characteristics, specifications, installation, wiring, and basic drive controller functions.

What's inside

  • Introduction
  • Receiving and Preliminary Inspection
  • Storing and Shipping
  • Technical Characteristics
  • Specifications
  • Installation
  • Wiring
  • Basic Drive Controller Functions
  • Programming and Setup
  • Maintenance and Troubleshooting

Specifications

Motor Power Range (Single-Phase Input)0.5 to 3 hp (0.37 to 2.2 kW)
Motor Power Range (Three-Phase Input)1 to 20 hp (0.75 to 15 kW)
Output Frequency0.5 to 400 Hz
Output Phases3
Switching Frequency2.0 to 15 kHz
Pollution Degree2
Maximum Ambient Temperature (Operation)+14 to +104 °F (-10 to +40 °C)

Frequently asked questions

What personnel should perform installation and maintenance?

Installation, adjustment, repair, and maintenance of the drive controllers must be performed by qualified personnel.

How long should one wait after disconnecting power before servicing?

You must wait three minutes for the DC bus capacitors to discharge before servicing.

What is the maximum relative humidity for the drive controller?

The maximum relative humidity is 93% maximum, non-condensing and without dripping.