Insulation Tester Instruction Manual Model 601E-60BX-000A

This file is about the instruction manual of the multimeter, which can measure voltage, current, resistance, diodes, etc. The measurement range is 250V/500V/1000V, and it can meet the needs of insulation resistance check for electricity, cables, electrical and mechanical equipment, telecommunication equipment and electrical facilities.


Insulation Tester Instruction Manual Model 601E-60BX-000A - cover page
Brand
Unknown
Category
Other Electronics
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
332 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
2B0DF47B5376900D23090ACA0B328FC1

About this manual

The document provides an instruction manual for the 601E-60BX-000A digital insulation tester. It details the instrument's features, including a high-stability DC voltage converter and digital bridge measurement capabilities. The manual outlines the front panel controls, such as voltage selection switches and resistance range selectors, and explains how to connect terminals for various measurements.

What's inside

  • General
  • Front Panel Description
  • Technical Property
  • Operation Description
  • Method to Measure Insulated Resistance
  • Safety Notes
  • Sets of Instrument
  • Fault Elimination

Specifications

Auto power offapprox. 15 minutes after turning on
Power consumptionless than 300mw at unload measurement
Operation environment temperature0°C —40°C
Measured voltage250V±10%, 500V±10%, 1000V±10%
Resistance range0.1MΩ—20MΩ, 0.1MΩ—50MΩ, 0.1MΩ—100MΩ, 20MΩ—500MΩ, 50MΩ—1000MΩ, 100MΩ—2000MΩ
Accuracy±(4% of reading ± 2 digits)
Shot current1.8mA
Median resistance2 MΩ
ACV Accuracy±(1.0% of reading + 6 digits)
Input impedance1MΩ
Frequency response50~200 Hz
Dimension175(L) ×110(W) ×70(D) mm
Weight630 g (including batteries)

Frequently asked questions

What is the auto power off time?

The instrument turns off automatically approximately 15 minutes after being turned on.

What is the accuracy of the resistance measurement?

The accuracy is ±(4% of reading ± 2 digits).

What should be done if the display shows '1'?

The '1' indicates an over-range condition, and the user should turn to a higher range to get a reading.

Download PDF (332 KB)