This document is an introduction to the In-Sight® Micro Series Vision System Installation Manual
This document provides step-by-step instructions for installing the Cognex In-Sight® Micro Series Vision System. It includes safety precautions, component details, cable connections, and regulatory compliance information. The guide covers installation of mounting blocks, lenses, I/O modules, Ethernet, and power connections, with specific notes for different models. It also includes dimensions and maintenance procedures.
| Power Source | IEEE 802.3af compliant, UL or NRTL listed, Power over Ethernet (PoE) power source rated Class 0, 2,3 or 4 |
|---|---|
| Cable Bend Radius | At least six inches from the connector |
| Regulatory Model | 1AAN |
An IEEE 802.3af compliant, UL or NRTL listed, Power over Ethernet (PoE) power source rated Class 0, 2,3 or 4 must be used.
You must use an IEEE 802.3af compliant, UL or NRTL listed, Power over Ethernet (PoE) power source rated Class 0, 2, 3 or 4.
The cable bend radius must begin at least six inches from the connector and be no tighter than 10 times the cable diameter.
No, you must not expose the image sensor to laser light, including direct or reflected light, as it can damage the sensor.