This manual introduces the operating instructions of the solenoid valve
This document provides operating instructions for the Bürkert Type 6027 2/2-way solenoid valve, including safety warnings, installation procedures, maintenance guidelines, and technical specifications. It emphasizes correct installation, electrical safety, and proper handling to prevent injury or equipment damage. The valve is designed for controlling neutral media up to a viscosity of 21 mm²/s and meets IP65 protection class when installed with a compatible cable plug.
| Voltage Tolerance | ±10% |
|---|---|
| Protection Class | IP65 |
| Maximum Ambient Temperature | +55 °C |
| Body Material | Brass (MS) or Stainless steel (VA) |
| Sealing Materials | EPDM, PTFE, FKM, PEEK, NBR |
| Operating Duration | Continuous operation |
The device satisfies protection class IP65 in accordance with DIN EN 60529 / IEC 60529 with cable plug, e.g. Bürkert Type 2508.
The maximum ambient temperature is +55 °C.
The body is made of Brass (MS) or Stainless steel (VA), and sealing materials include EPDM, PTFE, FKM, PEEK, and NBR.
Check whether the device has been installed according to the instructions, electrical and fluid connections are correct, the device is not damaged, all screws have been tightened, voltage and pressure are switched on, and pipelines are clean.