This document is the Type 2513 Device socket manual, which introduces the characteristics and usage of the product, including the intended use, scope of application, installation, operation, maintenance, etc.
This document provides safety and operating instructions for the Bürkert Type 2513 device socket, which complies with DIN EN 175301-803, Form A. It includes warnings for electrical and mechanical hazards, installation procedures, maintenance guidelines, and technical specifications. The device is rated for IP65 protection and operates in ambient temperatures from -30°C to +90°C. It is approved for use in Zone 2/22 per ATEX Cat. 3. Users must follow all safety precautions and not modify the device.
The manual also covers transport, storage, disposal, and troubleshooting. It specifies cable diameter (5.5–6.5 mm), wire cross-section (3 x 0.75 mm²), and maximum voltage (230 V AC/DC). Maintenance is maintenance-free under normal operation, but cleaning must be done with a moist or anti-static cloth. Contact Bürkert Service for malfunctions.
| Connection Diagram | According to DIN EN 175301-803, Form A |
|---|---|
| Number of Poles | 4-pole (2+2 protective conductor) |
| Cable Diameter | 5.5-6.5 mm |
| Wire Cross-Section | 3 x 0.75 mm² |
| Bending Radius | >= 10x cable diameter |
| Nominal Voltage | max. 230 V AC/DC |
| Voltage Tolerance | max. 10% U nom |
| Current Carrying Capacity | max. 4A |
| Degree of Protection | IP65 in the installed state |
| Ambient Temperature | -30°C to +90°C |
Maximum nominal voltage is 230 V AC/DC.
It has an IP65 rating in the installed state.
No, do not make any external modifications to the device.
Warranty is void if operating instructions are not followed.