Key facts
- Manuals
- 90
- Models
- 12
- Languages
- ZH · EN · FR · ES · PT · DE · SV
- Last added
- 2026-10-22
Bürkert models by category
Featured Bürkert manuals

Bürkert AirLINE 8652 Modular Valve Terminal User Manual
The Bürkert AirLINE 8652 is a modular valve terminal designed for the control and monitoring of pneumatically operated process valves. It supports various industrial communication protocols including PROFINET, EtherNet/IP, PROFIBUS DPV1, CC-Link, and büS (CANopen). The device allows for the integration of up to 48 valves and supports optional electronic modules with digital inputs and feedback sensors.
This document covers the entire lifecycle of the device, from installation in switchgear or on standard rails to electrical and pneumatic connections. It details configuration via the Web server, ME43 fieldbus gateway, and Bürkert Communicator software. The manual also includes procedures for commissioning, switching time monitoring, spare part replacement, and troubleshooting common error messages. This manual is written in Chinese.
Covers: Expected Use · Basic Safety Instructions · Product Description · Technical Data · Installation in Switchgear · Electrical Connections

Bürkert 8228 ELEMENT Q MultiCELL Transmitter/Controller Technical Data Sheet
The Bürkert 8228 ELEMENT Q is a multiCELL transmitter and controller designed for measuring conductivity and temperature in industrial and water treatment applications. It features a sensor with electromagnetic coils housed in PP, PVDF, or PEEK probes, capable of measuring conductivity from 0.1 µS/cm to 2 S/cm with a response time of 3 to 40 seconds. The device includes an integrated temperature probe for automatic compensation and supports pre-defined or custom compensation curves. This manual is written in Chinese.
Covers: Technical Specifications · Conductivity Measurement · Temperature Measurement · Installation Instructions · Material Compatibility · Electrical Parameters

Bürkert 8611 Process and Proportional Controller User Manual
The Bürkert 8611 eCONTROL is a process controller designed for use with proportional valves and process valves to control process variables such as pressure, temperature, or flow. It is intended for integration into closed-loop systems within fluid technology applications and supports various installation methods including wall mounting, DIN rail, valve, and cabinet mounting.
The document provides comprehensive instructions on system configuration, including setting control variables, scaling sensor inputs (4-20 mA or 0-10 V), and calibrating analog outputs. It also details operational modes, manual and automatic control structures, and troubleshooting procedures for the device. This manual is written in Chinese.
Covers: Expected Use · Basic Safety Instructions · System Overview · Technical Specifications · Installation · Electrical Installation

Bürkert AC21 Electromagnetic Coil User Manual
The Bürkert AC21 is an electromagnetic coil designed for use with solenoid valves in potentially explosive atmospheres. It holds Ex ia IIC T5/T6 certification and is suitable for both standalone and modular installations. The device operates within specific temperature ranges and power limits depending on the installation type. This manual is written in Chinese.
Covers: Intended Use · Basic Safety Instructions · Operating Conditions · Technical Data · Installation · Maintenance and Troubleshooting
Latest Bürkert manuals
Bürkert AirLINE 8652 Modular Valve Terminal User Manual
User Manual 122 pages · 15.6 MB · ZHThis manual provides installation, configuration, commissioning, maintenance, and troubleshooting instructions for the Bürkert AirLINE 8652 modular valve…
Bürkert 8228 ELEMENT Q MultiCELL Transmitter/Controller Technical Data Sheet
Product Leaflet 8 pages · 718 KB · ZHTechnical specifications and installation data for the Bürkert 8228 ELEMENT Q multiCELL transmitter/controller, covering conductivity and temperature…
Bürkert 8611 Process and Proportional Controller User Manual
User Manual 102 pages · 17 MB · ZHThis manual covers the installation, operation, configuration, and maintenance of the Bürkert 8611 eCONTROL process and proportional controller.
Bürkert AC21 Electromagnetic Coil User Manual
User Manual 16 pages · 1.6 MB · ZHThis manual provides operating instructions, safety guidelines, installation steps, and technical specifications for the Bürkert AC21 electromagnetic coil…
Bürkert 0127 Miniature Rocker Solenoid Valve Product Leaflet
Product Leaflet 4 pages · 329 KB · ENA highly reliable miniature rocker solenoid valve with low dead volume, suitable for laboratory and medical applications.
Bürkert 2031 Forged Valve Technical Data Sheet
Datasheet 12 pages · 405 KB · ENTechnical data sheet for the Bürkert 2031 forged diaphragm valve, detailing specifications, materials, and ordering information for DN 8-100 sizes.
Bürkert EPS 18 ATEX 1088X Operating Instructions
User Manual 14 pages · 646 KB · FROperating instructions for Bürkert EPS 18 ATEX 1088X, an explosion-proof device for hazardous areas.
Bürkert Type 8647 Valve Block AirLINE SP User Manual
User Manual 104 pages · 9.5 MB · FRUser manual for Bürkert Type 8647 valve block, compatible with Siemens SIMATIC ET 200SP systems.
Bürkert 8228 Inductive Conductivity Meter User Manual
User Manual 70 pages · 3.2 MB · ESThis user manual provides instructions for the operation, installation, adjustment, and maintenance of the Bürkert ELEMENT 8228 inductive conductivity meter.
Bürkert 0142 Solenoid Valve User Manual
User Manual 13 pages · 620 KB · FRUser manual for Bürkert 0142 2/2-way solenoid valve, covering installation, operation, safety, and maintenance.
Bürkert Type 5404 Solenoid Valve Operating Instructions
User Manual 16 pages · 1.2 MB · FROperating instructions for the Bürkert Type 5404 2/2-way solenoid valve, covering safety, installation, and maintenance.
Bürkert 6164 2/2 or 3/2-way cartridge valve manual
User Manual 17 pages · 2 MB · FRUser manual for Bürkert 6164 2/2 or 3/2-way cartridge valve, covering installation, maintenance, safety, and technical specs.
Bürkert 8741/8742 büS/CANopen Mass Flow Meter/Controller Operating Instructions
User Manual 45 pages · 3.9 MB · PTOperating instructions for the Bürkert 8741/8742 büS/CANopen Mass Flow Meter (MFM) and Mass Flow Controller (MFC), covering installation, operation, and…
Bürkert S030 INLINE Fitting Operating Instructions
User Manual 11 pages · 600 KB · ENOperating instructions for the Bürkert S030 INLINE fitting, covering safety, installation, maintenance, and technical data for flow measurement.
Bürkert Type 2513 Device Socket Operating Instructions
User Manual 9 pages · 351 KB · DEOperating instructions for the Bürkert Type 2513 device socket, covering safety, installation, electrical connection, and maintenance according to DIN EN…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Datasheet
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in Bürkert manuals
What materials are available for the conductivity probe?
The probe is available in PP, PVDF, or PEEK materials.
From: Bürkert 8228 ELEMENT Q MultiCELL Transmitter/Controller Technical Data Sheet
Does the device support temperature compensation?
Yes, it supports pre-defined curves (NaCl, NaOH, HNO3, H2SO4) or custom actual process temperature compensation.
From: Bürkert 8228 ELEMENT Q MultiCELL Transmitter/Controller Technical Data Sheet
Can the 8611 controller be used outdoors?
No, the device must not be used outdoors.
From: Bürkert 8611 Process and Proportional Controller User Manual
What are the installation methods supported?
The controller supports wall mounting, DIN rail mounting, valve mounting, and cabinet mounting.
From: Bürkert 8611 Process and Proportional Controller User Manual
What is the intended use of the AC21 coil?
The device is used exclusively as a solenoid valve for media listed in the data sheet within explosion protection groups II, category 2G.
Can the AC21 coil be used in non-Ex circuits?
No, devices used in non-Ex circuits must not be reused in Ex circuits as they cannot guarantee safety.