This manual introduces the use of the SolarEdge Energy Meter with Modbus connection
This document provides installation instructions for the SolarEdge Energy Meter with Modbus Connection, designed for use in Europe, APAC, and South Africa. The guide covers safety instructions, package contents, and metering applications such as production metering and consumption monitoring. It details the required Current Transformers (CTs) for single-phase and three-phase grids.
| Operating Voltage Range | 184-264.5 / 320-460Vac |
|---|---|
| AC Frequency | 45/65 Hz |
| Power Consumption | 3 W |
| Response time | ≤200 ms |
| Default Device ID (Modbus) | 2 |
| RS485 Termination | 120 ohm |
| Accuracy | ±1.0 % |
| Dimensions | 75 x 138.6 x 35 mm |
| Weight | 0.20 gm |
| Operating Temperature Range | -40 to +85 °C |
The meter supports RS485 half-duplex with 3 wires (A, B, GND).
Three CTs are required when used in a three-phase grid.
The accuracy is ±1.0% for 1% to 100% of Rated CT Current.