This is a battery wiring guide and contains an on-site checklist with steps for post-installation verification of a StorEdge system for the following batteries: LG Chem RESU7H/RESU10H
This document serves as a wiring guide and on-site checklist for the SolarEdge StorEdge Inverter, specifically designed for use with LG Chem RESU7H and RESU10H batteries. It details the required cable types, connector configurations, and wiring diagrams for systems with two or three DIP switches. The guide also includes specific safety warnings regarding battery disconnection to prevent deep discharge.
| Recommended DC Cable Cross Section | 6 mm2 (2.5-6 mm2), 600V insulated |
|---|---|
| Recommended Ground/PE Cable Cross Section | 6-10mm2, 600V insulated |
| Recommended Control and Monitoring Cable | 5-wire shielded twisted pair cable, 0.2 mm2 |
| Compatible Battery Models | LG Chem RESU7H/RESU10H |
Before wiring the system, make sure that the battery is powered off, using both the auxiliary power supply switch and the circuit breaker switch.
Extended battery disconnection may result in deep discharge and damage the battery.
The recommended minimum cross-section is 6 mm2.