This document introduces the test method for AQ-170-BG Corn Bulk Grain HS Enogen product.
The document outlines a specific test procedure for detecting Enogen in corn bulk grain samples. It details the requirements for sample collection, grinding, and sub-sampling to ensure accuracy, specifying that at least 95% of the ground sample must pass through a 20 mesh sieve.
The guide describes the step-by-step process for preparing the test extract using EB17 pouches and distilled water. It includes specific instructions on shaking, centrifugation (at 2000 x g), incubation at 22°C, and the final reading steps using a QuickScan device to determine if the result is below or above 0.04%.
You must collect and grind a representative corn sample so that at least 95% of it passes through a 20 mesh sieve.
Add one dissolvable pouch of EB17 and 75 mL of distilled, deionized, or bottled water to the container.
The incubator must reach 22°C, and acclimation is required if the ambient temperature is unknown or outside the 20-24°C range.
The QuickScan will return a result that is either less than 0.04% or greater than 0.04%.