Chint DDSU666 Single Phase Smart Meter Operation Manual

DDSU666 single phase smart meter operation manual, this manual introduces the product functions, installation, use, maintenance and other content


Chint DDSU666 Single Phase Smart Meter Operation Manual - cover page
Brand
CHINT
Document type
User Manual
Language
English
Pages
23
File format
PDF
File size
746 KB
Published
16 October, 2023
Updated
16 October, 2023
Model
DDSU666
MD5 checksum
FD906559FBF8F28EAC8C1CE54E886CE0

About this manual

The Chint DDSU666 is a single-phase electronic energy meter designed for power monitoring and energy metering in electric power systems. It features an RS485 communication interface compliant with the Modbus-RTU protocol and utilizes standard DIN35mm rail mounting for easy installation. The device measures parameters such as voltage, current, active power, frequency, and power factor.

What's inside

  • Brief Introduction
  • Working Principle
  • Main Technical Performance & Parameters
  • Displayed functions
  • Communication function
  • Keyboard operation
  • Appendix A: Communication protocol

Specifications

Accuracy class (Direct connection)Class B
Operating voltage range (Specified)0.9Un~1.1Un
Measuring range0~999999.99 kWh
Communication baud rates1200, 2400, 4800, 9600 bps
Maximum connected instruments32

Frequently asked questions

What is the maximum transmission distance for the communication line?

The maximum transmission distance should not exceed 1200m.

What is the update speed of active power?

The update speed of active power is better than 120ms.