Hunter Industries ACC Decoder System Troubleshooting Guide

ACC Decoder System Troubleshooting Guide, Finding a Break in the 2-Wire Path


Hunter Industries ACC Decoder System Troubleshooting Guide - cover page
Brand
Hunter Industries
Document type
Service Manual
Language
English
Pages
5
File format
PDF
File size
123 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
C5CFDC3188554A065793869165871713

About this manual

This document serves as a troubleshooting guide for the Hunter Industries ACC Decoder System. It details specific diagnostic procedures for common issues such as finding breaks or short circuits in the two-wire path, identifying decoders that fail to activate valves or relays, and resolving communication errors.

The guide provides step-by-step instructions on using tools like digital multimeters (DMM) with Min/Max functions, clamp-on current sensors, and cable tracers. It includes voltage and resistance thresholds for various components, such as the ADM module, solenoids, and wire pairs, along with a summary table of causes and fixes for specific fault messages.

What's inside

  • Finding a Break in the 2-Wire Path
  • Decoder or Decoders do not activate a valve/relay
  • Station Fault – (Overcurrent)
  • ADM / Decoder Module Alarm (Overcurrent)
  • Find a Short on the 2-Wire Path
  • Station Fault – Comm
  • Decoder not Programming on Programming Port

Specifications

ADM Output Voltage Range32V to 36V
Two-Wire Path Voltage Range20V to 36V
Decoder Wire Resistance (per 1000ft)5.04 ohms (#14-2 gauge)
Solenoid Resistance Range20 – 35 ohms
Programming Port Voltage Range13V to 16V Max and -13V to -16V Min
Short Circuit Resistance ThresholdLess than 10k ohms

Frequently asked questions

What voltage should be read across the blue and red terminals of the ADM?

The voltage should read between 32V to 36V.

What is the acceptable resistance range for a single solenoid?

A single solenoid will have 20 – 35 ohms of resistance depending on the type.

What indicates a short circuit in the two-wire path?

If the resistance reads less than 10k (10,000) ohms on any of the paths.

How can you verify if a decoder is alive using the Programming Port?

Measure the port voltage; it should be between 13V and 16V Max and -13V to -16V Min.