Residential Sprinkler System Design and Installation Guide

This manual introduces the design and installation of residential sprinkler systems, including the capacity of the system, the selection of sprinkler heads, the division of the system, valves and pipes, electrical connections, and system debugging.


Residential Sprinkler System Design and Installation Guide - cover page
Brand
Hunter Industries
Document type
User Manual
Language
English
Pages
32
File format
PDF
File size
8.5 MB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
9B9ABCAA2F5C4159F9D66F3F2BAB84AA

About this manual

This booklet is intended to assist users in designing and installing small single-family residential sprinkler systems. It provides an easy-to-follow format with illustrations and charts to help plan the system layout, determine water capacity, select appropriate sprinkler heads, and design zones.

The guide details the installation process for main lines, valve manifolds, lateral lines, and sprinkler heads. It also includes sections on making point-of-connections, installing controllers (including Wi-Fi considerations), and provides a materials list for ordering parts.

What's inside

  • Sprinkler System Planning
  • Determine System Design Capacity
  • Select Sprinkler Heads
  • Divide Sprinklers into Zones
  • Locate Valves – Lay Out and Size Pipes
  • Making the Point of Connection
  • Installing the Main Line
  • Installing the Valve Manifolds
  • Installing Sprinkler Heads/Backfilling
  • Watering Guidelines

Frequently asked questions

What is the recommended working pressure for choosing sprinkler heads?

The guide recommends using the approximate working pressure at the head as a guide when selecting components.

What is the recommended method for measuring the circumference of a service line to determine its size?

Wrap a piece of string around the pipe, measure the string, and use the provided table to convert the length to pipe size.

What are the most common sizes for residential water meters?

The most common sizes for residential meters are 15 mm, 20 mm, and 25 mm.

What is the maximum recommended length for a copper service line if you do not deduct the flow rate for copper pipe?

The length of copper service line should not exceed 15 m if you decide not to deduct the 7.6 l/min.