This is the April 2015 release Revision A of the Trimble S7 Total Station user guide
The document serves as a comprehensive user manual for the Trimble S7 Total Station. It covers essential topics including safety information regarding laser radiation and battery handling, initial inspection and care procedures, and detailed steps to get started with the device.
Key operational areas addressed include instrument setup (leveling, stability), connecting controllers like the Trimble CU or TSC3, utilizing advanced technologies such as Autolock, FineLock, and VISION for measurement, and managing power through internal or external batteries. The guide also details accessory usage and troubleshooting.
| Laser Class (Distance) | LASER CLASS 1 |
|---|---|
| Laser Class (Pointer) | CLASS 2 LASER PRODUCT |
| Wavelength (Distance) | 905 nm |
| Wavelength (Pointer) | 630 - 680 nm |
| Maximum output power (Distance) | <1.1 mW |
| Maximum output power (Pointer) | <0.7 mW |
The maximum output power for the distance measuring function is less than 1.1 mW.
No, these two functions cannot operate at the same time.
Immediately rinse your eyes with clean water and seek medical attention without rubbing.