This document is the user manual of SOYAL ACCESS CONTROL SYSTEM ® AR-401RO16B, which includes product introduction and specification parameters.
This document is a user guide for the Soyal AR-401RO16B, a relay output module designed for elevator control systems. It provides technical specifications including RS-485 communication capabilities, 16 Form C relay outputs, and power supply requirements ranging from +9V to +24V DC.
The guide details the configuration of the Node ID using DIP switches and jumpers, specifying compatibility with various Soyal controller models such as the AR-321H, AR-721H, and AR-829E. It includes wiring diagrams for connecting lift buttons in both common point and non-common point configurations, along with specific settings for baud rates (4800bps or 9600bps) and relay types (NC or NO).
| Communication | RS-485 |
|---|---|
| Baud Rate | 4800bps/9600bps/19200bps |
| Channels | 16 Form C Relay Output |
| Power Supply | +9 ~ +24V DC |
| Contact Rating (AC) | [email protected] |
| Contact Rating (DC) | 24V@2A |
| Dimensions | 180(L) x 231(W) x 62(H) mm |
| Weight | 1,780+10g |
For elevator control, the baud rate should be set to 4800bps and DIP SW5 switched to ON.
It applies to models including AR-721H, AR-321H, AR-725H, AR-727H, AR-327H, AR-757H, AR-821EF, AR-829E, and AR-725E.
The module has 16 relay outputs, with 16 COM points dispatched separately to each relay.