Rotronic XB32A Humidity Temperature Transmitter User Guide

This manual introduces the overview, dimensional drawing, general description, user configurable settings and functions, mechanical installation, electrical installation, operation and firmware update of XB32A humidity temperature transmitter.


Rotronic XB32A Humidity Temperature Transmitter User Guide - cover page
Brand
Rotronic
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
812 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
36DF20E50A4B797EC916CCE9B572219F

About this manual

The Rotronic XB32A is a humidity and temperature transmitter designed for OEM applications. It features a probe with an integrated capacitive humidity sensor (HYGROMER® HT-1) and a Pt100 RTD for temperature measurement, capable of measuring relative humidity from 0 to 100 %RH and temperatures from -100 to 200 °C. The device utilizes ROTRONIC AirChip 3000 digital technology to provide linear analog outputs (voltage or current) and supports various functions such as dew point calculation, automatic sensor testing, and data recording.

What's inside

  • Overview
  • Dimensional drawings
  • General description
  • User configurable settings
  • Mechanical installation
  • Electrical installation
  • Operation
  • Firmware updates
  • Technical data

Specifications

Measured Humidity Range0 to 100 %RH
Measured Temperature Range-100 to 200 °C
Power Supply (3-wire)15 to 40 VDC or 13 to 28 VAC
Humidity Sensor TypeROTRONIC HYGROMER® HT-1 capacitive sensor
Temperature Sensor TypePt100 RTD

Frequently asked questions

What is the maximum current consumption of the XB32A?

With both output circuits closed, the maximum current consumption is 50 mA.

Can the XB32A calculate dew point or frost point?

Yes, using the ROTRONIC HW4 software, the transmitter can be configured to calculate either the dew point or the frost point.

What is required to protect the sensors against dust particles?

A dust filter is required; the probe includes a metal carrier SPA-SS, and the filter insertion must be ordered separately.

Download PDF (812 KB)