This manual contains information on the use, maintenance and troubleshooting of the Marlow Series 20EVP pump.
Congratulations on your new Goulds Water Technology pump. This document serves as a guide to ensure maximum performance by following specific precautions regarding pressure limits, fluid temperature, electrical wiring, and modifications. The pump is designed primarily for water use, though other liquids may be pumped with caution and prior consultation.
The manual covers proper location and piping requirements, including the installation of strainers and check valves. It details operating procedures such as priming, checking rotation direction, and winter storage protocols to prevent damage from freezing or overheating.
| Strainer Mesh Size | 16 mesh |
|---|---|
| Strainer Depth | one foot below liquid level |
All motors require a magnetic starter with current overload protection.
Stop the pump immediately, allow it to cool, and slowly vent the pump.
Drain all liquid from the pump tank to prevent ice from cracking the tank or internal parts.