This document is about the repair manual of e-SV series pumps
This document provides repair stack installation instructions for the Goulds Water Technology Model e-SV series of vertical multi-stage pumps. It must be used in conjunction with the Installation, Operation and Maintenance manual.
The guide details safety precautions, procedures for removing the pump stack (including motor removal and seal gland/cartridge seal handling), and step-by-step instructions for installing a new repair stack. It covers specific variations for 1-22SV units versus 33-125SV units.
This document covers vertical, multi-stage pumps.
The tie rod nuts should be tightened in small increments in a diagonal pattern to ensure proper seating.
A water-based lubricant should be used to lightly lubricate the shaft or sleeve.