Goulds e-SV Series Vertical Multi-Stage Pump Repair Stack Instructions

This document is about the repair manual of e-SV series pumps


Goulds e-SV Series Vertical Multi-Stage Pump Repair Stack Instructions - cover page
Brand
Goulds Water Technology
Document type
Service Manual
Language
English
Pages
4
File format
PDF
File size
242 KB
Published
15 October, 2023
Updated
15 October, 2023
MD5 checksum
C6D22B0ACDD4CFECD623C20F315E610A

About this manual

This document provides repair stack installation instructions for the Goulds Water Technology Model e-SV series of vertical multi-stage pumps. It must be used in conjunction with the Installation, Operation and Maintenance manual.

The guide details safety precautions, procedures for removing the pump stack (including motor removal and seal gland/cartridge seal handling), and step-by-step instructions for installing a new repair stack. It covers specific variations for 1-22SV units versus 33-125SV units.

What's inside

  • REPAIR STACK INSTALLATION INSTRUCTIONS
  • SAFETY INSTRUCTIONS
  • PUMP STACK REMOVAL
  • REPAIR STACK INSTALLATION
  • Seal Gland or Cartridge Seal Re-installation

Frequently asked questions

What type of pump does this repair stack instruction cover?

This document covers vertical, multi-stage pumps.

How should the tie rod nuts be tightened during installation?

The tie rod nuts should be tightened in small increments in a diagonal pattern to ensure proper seating.

What lubricant is recommended for installing the seal seat on 33-125SV units without a cartridge seal?

A water-based lubricant should be used to lightly lubricate the shaft or sleeve.