This is an instruction manual for installation, operation and maintenance of deep well turbine pumps
The document serves as a comprehensive instruction manual for Goulds Water Technology's Deep Well Turbine (DWT) pumps. It provides guidance on proper installation, startup procedures, routine maintenance, and troubleshooting to ensure long-term trouble-free service. The text emphasizes safety precautions regarding hazardous voltage and mechanical handling.
Insulated work gloves are needed for hot sand collars, heavy work gloves for sharp edges like impellers, safety glasses with side shields, and steel-toed shoes.
The pump and bowl assembly shafting shall be rotated counter clockwise at least once a month.