This is the operating manual for the 3755 model of the three-ring pump
The document serves as a comprehensive guide for the safe handling of the Model 3755 pump. It details critical safety warnings regarding pressure vessels, hazardous fluids, and electrical hazards, emphasizing the importance of adhering to specific operational limits to prevent injury or equipment damage.
The manual provides step-by-step instructions for installation, including foundation preparation, alignment procedures, and piping connections. It further outlines preparation steps such as priming and adjusting stuffing box glands before starting the pump.
Operators must use insulated work gloves for hot bearings, heavy work gloves for sharp edges like impellers, safety glasses with side shields, and steel-toed shoes.
No, applying heat to impellers or retaining devices is strictly forbidden because trapped liquid can expand and cause a violent explosion.
You must always lock out power to the driver to prevent electric shock, accidental start-up, and physical injury.