Goulds Pumps Model 3189 Safety Manual

This document mainly introduces the safe use methods of ITT Goulds Pumps products


Goulds Pumps Model 3189 Safety Manual - cover page
Brand
Goulds Pumps
Document type
Service Manual
Language
English
Pages
32
File format
PDF
File size
5.7 MB
Published
15 October, 2023
Updated
15 October, 2023
MD5 checksum
CE07C9E20C7D7D3EFC983E736FF27E9C

About this manual

This document serves as a Pump Safety Manual for the Goulds Model 3189 series. It outlines specific safety risks associated with pumping equipment, including pressure vessel hazards, blocked flow conditions, and exposure to hazardous fluids.

The manual defines standard warning terms such as WARNING, CAUTION, ELECTRICAL HAZARD, and ATEX to guide operators on necessary precautions. Key general precautions include never applying heat to remove impellers due to explosion risks from trapped liquid, always locking out driver power before maintenance, and ensuring coupling guards are correctly installed during operation.

What's inside

  • Foreword
  • Important Safety Notice
  • Safety Warnings
  • Safety Definitions
  • General Precautions
  • Receiving
  • Alignment
  • Piping
  • Startup and Operation

Frequently asked questions

What is the primary responsibility of the end user regarding this equipment?

Safe installation, operation, and maintenance are an essential end user responsibility.

Why must heat never be applied to impellers for removal?

Applying heat is forbidden because trapped liquid can rapidly expand and result in a violent explosion.

Download PDF (5.7 MB)

More Goulds Pumps Manuals