This document is the user manual of Fluke 867B/863 Graphical Multimeter, introducing the product features and usage methods
This document serves as the user manual for the Fluke 867B and 863 Graphical Multimeters. It covers the device's features, including Combo, Meter, View, and Trend display modes, as well as specific functions like Auto Diode Test, Logic Test, and Component Test. The guide details how to make various measurements, such as AC/DC Volts, Amps, Ohms, Frequency, and Capacitance.
| Display | LCD - Dot Matrix, 240 X 200 pixels |
|---|---|
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -20°C to 60°C |
| Input Impedance | 10 MΩ |
| AC Volts Accuracy (300.00 mV) | 1.5% + 10 |
| DC Volts Accuracy (300.00V) | 0.025% + 2 |
| Diode Test Resolution | 0.0001V |
The warranty period is three years and begins on the date of shipment.
You can locate an authorized service center by visiting the Fluke website or calling the provided phone numbers.
The device operates within a temperature range of 0°C to 50°C.