Beacon Global Technology BT-MT-101-S Gateway Product Manual

This document describes the features and characteristics of Beacon Global Technology's BT-MT-101-S Modbus TCP-IEC 60870-5-101 Serial Communication Gateway Module. The gateway supports bidirectional data exchange between devices in Modbus TCP and IEC 60870-5-101 networks, with a maximum data exchange area of 20,000 bytes. The gateway provides one Modbus TCP Ethernet port and two IEC 60870-5-101 serial ports for communication with PLCs, HMIs, frequency converters, operator stations, and devices with IEC 60870-5-101 interfaces. The gateway can be configured and diagnosed through a web page without the need for special software. The gateway supports a wide input power range and extended temperature range, and comes with a 3-year quality guarantee.


Beacon Global Technology BT-MT-101-S Gateway Product Manual - cover page
Brand
Beacon Global Technology
Category
Industrial Supply
Document type
Product Leaflet
Language
Chinese
Pages
2
File format
PDF
File size
449 KB
Published
13 January, 2023
Updated
28 September, 2023
MD5 checksum
D0C72E58E0C0E08F68989EB6EE29F7A9

About this manual

The Beacon Global Technology BT-MT-101-S is a gateway module designed for bidirectional data exchange between devices on Modbus TCP and IEC 60870-5-101 networks. It features one Ethernet port and two configurable IEC 60870-5-101 serial ports, supporting up to 10 clients and 10 servers simultaneously for Modbus TCP, and up to 1000 commands per master port for IEC 60870-5-101. The device includes a 20,000-byte data exchange area and an SD card slot for quick configuration recovery. This manual is written in Chinese.

What's inside

  • Product Specifications
  • IEC-60870-5-101 Master Protocol
  • IEC-60870-5-101 Slave Protocol
  • Modbus TCP Specifications
  • Hardware Specifications
  • LED Indicators
  • Ethernet Port
  • Serial Ports
  • Certifications
  • Contact Information

Specifications

Data Exchange Area20,000 bytes
Ethernet Port10/100Mbit
Modbus TCP Clients10
Modbus TCP Servers10
IEC 60870-5-101 Master Commands1000
Power Supply Range10-36 VDC
Operating Temperature-35°C to 75°C
Dimensions54.2 x 106.1 x 145.4 mm

Frequently asked questions

What is the maximum data exchange area size?

The maximum data exchange area is 20,000 bytes.

How many Modbus TCP clients and servers can be supported simultaneously?

It supports up to 10 clients and 10 servers simultaneously.

Can the IEC 60870-5-101 serial ports be configured as master or slave?

Yes, the two IEC 60870-5-101 serial ports can be configured as master or slave according to customer requirements.

What is the operating temperature range?

The operating temperature range is from -35°C to 75°C.