IDEXX QC Fecal Coliform Control Standard Kit User Manual

The IDEXX-QC Fecal Coliform Control Standard Kit is a set of cultured bacteria used for quality control testing and standard performance evaluation. The product contains active Escherichia coli and Pseudomonas aeruginosa and should be operated at room temperature. This product can be used for the preparation and testing of fecal coliform control samples.


IDEXX QC Fecal Coliform Control Standard Kit User Manual - cover page
Brand
Idexx
Category
Other
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
535 KB
Published
09 October, 2022
Updated
28 September, 2023
MD5 checksum
3EA829B7C1192B89EADCB843DBFC0099

About this manual

The IDEXX QC Fecal Coliform Control Standard Kit is a set of cultured bacteria designed for quality control testing and standard performance evaluation. It provides both positive and negative controls containing active microorganisms located in colored discs within small vials containing silica desiccant. The kit includes three tubes of Escherichia coli and three tubes of Pseudomonas aeruginosa. It is intended for use by trained laboratory personnel in laboratories with microbiological testing capabilities and must be handled according to appropriate biosafety regulations.

To use the kit, the vials must be stored at ≤-10°C and allowed to equilibrate to room temperature for 10-15 minutes before opening. One colored disc is transferred aseptically into a bottle containing 100ml of IDEXX sterile rehydration buffer or sterile, non-buffered, non-oxidizing water. The sample is mixed by inverting the bottle 10 times after the disc dissolves. The rehydrated sample must be used within 30 minutes. For testing, the sample is mixed with Colilert reagent, poured into a 97-well quantitative plate, sealed, and incubated at 44.5°C for 24 hours. Results are read as yellow for fecal coliforms, and the final result is obtained by consulting an MPN table. This manual is written in Chinese.

What's inside

  • Product Information
  • Packaging
  • Precautions
  • Storage Conditions
  • Rehydration Instructions
  • Testing Procedure
  • Result Reading

Specifications

Contents3 tubes of Escherichia coli, 3 tubes of Pseudomonas aeruginosa
Storage Temperature≤-10°C
Rehydration Volume100ml
Equilibration Time10-15 minutes
Usage WindowWithin 30 minutes
Incubation Temperature44.5°C
Incubation Time24 hours

Frequently asked questions

What is the IDEXX QC Fecal Coliform Control Standard Kit used for?

It is used for quality control testing and standard performance evaluation of fecal coliform detection.

What organisms are included in the kit?

The kit contains Escherichia coli and Pseudomonas aeruginosa.

How should the control standard vials be stored?

The vials must not be opened and must be stored at ≤-10°C to remain stable within the expiration date.

What indicates a positive result for fecal coliforms?

A yellow color indicates the presence of fecal coliforms.