Featured Idexx manuals

IDEXX Filta-Max xpress v2.0 Operation Manual
This manual describes the Filta-Max xpress v2.0 rapid washing device, its purpose, safety precautions, and required consumables. It explains how the system removes Cryptosporidium and Giardia cysts from water samples ranging from 10 to 1000 L, and lists the equipment, reagents, and accessories needed.
Detailed operating procedures cover filter installation, sample collection, buffer preparation, system initialization, washing cycles, and post‑run cleaning. The document also includes routine maintenance schedules, monthly service steps, and a comprehensive troubleshooting appendix for common error messages. This manual is written in Chinese.
Covers: 设备组成 · 设备、耗材和试剂 · 操作压力 · 滤芯安装及取样过滤 · 快速连接装置装配 · 缓冲液配置

IDEXX Catalyst Dx Biochemical Analyzer Operation Guide
The Catalyst Dx is a veterinary biochemical analyzer that uses dry‑chemistry test strips to deliver up to 25 tests per sample. It connects to the IDEXX VetLab Station for data management and can be linked with multiple analyzers.
This manual covers safety precautions, installation, power requirements, startup and shutdown procedures, sample preparation, quality‑control steps, consumable information, routine maintenance, fan‑filter cleaning, software upgrades, and detailed troubleshooting guidance. This manual is written in Chinese.
Covers: Introduction · Safety Precautions · International Symbol Explanation · Getting Started Guide · Analyzer Components · Installation
Latest Idexx manuals
IDEXX Filta-Max xpress v2.0 Operation Manual
User Manual 14 pages · 547 KB · ZHThe IDEXX Filta-Max xpress v2.0 operation manual provides setup, safety, usage, maintenance, and troubleshooting instructions for rapid washing of…
IDEXX Catalyst Dx Biochemical Analyzer Operation Guide
User Manual 76 pages · 6.1 MB · ZHThe IDEXX Catalyst Dx Biochemical Analyzer Operation Guide provides safety instructions, setup, sample handling, quality control, maintenance, and…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Idexx manuals
How long can the filter cartridge be reused for system initialization?
A blank filter cartridge used only for system initialization and pipe cleaning can be reused for up to one month.
How often should the fan filter be cleaned?
The fan filter should be cleaned quarterly, or monthly if the analyzer is operated in a dusty or dirty environment.
From: IDEXX Catalyst Dx Biochemical Analyzer Operation Guide
What are the power requirements of the Catalyst Dx analyzer?
The analyzer requires 100‑240 V AC, 50‑60 Hz input and draws about 3.5 A.
From: IDEXX Catalyst Dx Biochemical Analyzer Operation Guide