Jingchuang KCM-XJ16 Series Temperature Patrol Detection Instrument User Manual

This document is the user manual for the KCM-XJ16 series universal input temperature patrol detection instrument produced by Yuyao Jingchuang Instrument Co., Ltd. The instrument has the functions of multiple signal free input and supports RS485 communication compatible with MODBUS-RTU protocol. The specific technical specifications include accuracy, input signal, temperature measurement range, channel quantity, etc. It can be used for parameter setting, fixed point display of inspection channels, inspection alarm, etc.


Jingchuang KCM-XJ16 Series Temperature Patrol Detection Instrument User Manual - cover page
Brand
Jingchuang
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
571 KB
Published
02 October, 2022
Updated
28 September, 2023
MD5 checksum
A5DE06F28177FE557BE9AF1679A7EE31

About this manual

The Jingchuang KCM-XJ16 series is a universal input temperature patrol detection instrument designed for temperature measurement and monitoring. It supports various input signals including thermocouples (K, E, J, R, S) and resistance thermometers (Pt100, Cu50). The instrument features dual-row digital displays for simultaneous viewing of measurement values and channel numbers, allowing for manual or automatic channel patrolling. This manual is written in Chinese.

What's inside

  • Overview
  • Main Technical Indicators
  • Panel Layout
  • Operation
  • Parameter Settings
  • Wiring
  • Troubleshooting
  • Modbus RTU Communication

Specifications

Accuracy± 0.5%F·S±1.0 digit
Input SignalsK, E, J, R, S, Pt100, Cu50
Temperature Range (K)-30~1300℃
Temperature Range (Pt100)-200.0~600℃
Max Channels16
Relay Capacity220V 5A (Resistive)
Dimensions160x80x85 mm
Power SupplyAC 220V±10% 50HZ
Operating Temperature0~50℃
Communication ProtocolRS485, MODBUS-RTU

Frequently asked questions

How do I enter the parameter menu?

Press the SET key for 3 seconds to enter the parameter menu.

What is the communication baud rate?

The baud rate is adjustable among 1200, 2400, 4800, and 9600.

What does the display show when the value is out of range?

The display shows 'HH' for exceeding the upper range and 'LL' for exceeding the lower range.

How many channels can the instrument support?

The instrument supports up to 16 channels.