This document is the installation manual for Aqua Logic Automation and Chlorination System, model AQL-P-4 LD GC. The manual provides basic safety instructions and describes the features and characteristics of the product.
This manual provides installation instructions for the Goldline AQL-P-4 control unit, which manages pool and spa automation and chlorination. The document details the preparation of pool water chemistry, specifically salt levels for the optional chlorinator function, and lists components included in the package versus those required separately.
| Operating Salt Level | 2700-3400 PPM |
|---|---|
| Optimal Salt Level | 3200 PPM |
| Free Chlorine Level | 1.0 to 3.0 ppm |
| pH Level | 7.2 to 7.6 |
| Cyanuric Acid Level | 60 to 80 ppm |
| Total Alkalinity Level | 80 to 120 ppm |
| Calcium Hardness Level | 200 to 400 ppm |
Salt is required only if you are using the chlorinator features on the Aqua Logic Control.
The water is properly balanced if the saturation index (Si) is 0 to +0.2.
If the Si is below -0.2, the water is corrosive and plaster pool walls will be dissolved into the water.