Goldline AQL-P-4 Pool Control Installation Manual

This document is the installation manual for Aqua Logic Automation and Chlorination System, model AQL-P-4 LD GC. The manual provides basic safety instructions and describes the features and characteristics of the product.


Goldline AQL-P-4 Pool Control Installation Manual - cover page
Brand
Goldline
Category
Other products
Document type
Installation Guide
Language
English
Pages
33
File format
PDF
File size
514 KB
Published
06 August, 2012
Updated
29 September, 2023
Model
AQL-P-4
MD5 checksum
86DDA698D5E2F0C7BC8E08D42DD0B185

About this manual

This manual provides installation instructions for the Goldline AQL-P-4 control unit, which manages pool and spa automation and chlorination. The document details the preparation of pool water chemistry, specifically salt levels for the optional chlorinator function, and lists components included in the package versus those required separately.

What's inside

  • Preparing Pool/Spa Water
  • Mounting Equipment
  • Plumbing
  • Electrical Wiring
  • Configuration
  • System Startup and Checkout
  • Warranty
  • Grounding and Bonding
  • Circuit Breaker Installation
  • Service Mode

Specifications

Operating Salt Level2700-3400 PPM
Optimal Salt Level3200 PPM
Free Chlorine Level1.0 to 3.0 ppm
pH Level7.2 to 7.6
Cyanuric Acid Level60 to 80 ppm
Total Alkalinity Level80 to 120 ppm
Calcium Hardness Level200 to 400 ppm

Frequently asked questions

Is salt required for the Aqua Logic system?

Salt is required only if you are using the chlorinator features on the Aqua Logic Control.

What is the ideal saturation index for pool water?

The water is properly balanced if the saturation index (Si) is 0 to +0.2.

What happens if the saturation index is below -0.2?

If the Si is below -0.2, the water is corrosive and plaster pool walls will be dissolved into the water.