CLARE PM1204 AC Power Switch Datasheet

The PM1204 is an AC Solid State Switch using optical coupling with dual power SCR outputs to provide an alternative to optocoupler and Triac circuits. The PM1204 switches are robust enough to provide a blocking voltage of up to 400V. In addition, tightly controlled zero cross circuitry ensures switching of AC loads without the generation of transients. The input and output circuits are optically coupled to provide 3750V of isolation and noise immunity between control and load circuits. As a result the PM1204 is well suited for industrial environments where electromagnetic interference could disrupt the operation of electromechanical relays.


CLARE PM1204 AC Power Switch Datasheet - cover page
Brand
CLARE
Document type
Datasheet
Language
English
Pages
5
File format
PDF
File size
125 KB
Published
02 August, 2012
Updated
29 September, 2023
MD5 checksum
71239AFC44F4C62488D14EA939962B28

About this manual

The CLARE PM1204 is a solid-state AC power switch designed to provide an alternative to traditional optocoupler and Triac circuits. It utilizes optical coupling with dual power SCR outputs to ensure robust performance in industrial environments, offering high noise immunity and low EMI generation.

Key features include zero-crossing detection for switching AC loads without generating transients, 400V blocking voltage capability, and TTL/CMOS compatible inputs. The device is available in 6-pin DIP and surface mount packages.

What's inside

  • Features
  • Applications
  • Description
  • Approvals
  • Ordering Information
  • Pin Configuration
  • Absolute Maximum Ratings
  • Electrical Characteristics

Specifications

Input Control Current (Normal)5 to 50 mA
Operating Temperature Range-40 to +85 °C

Frequently asked questions

Does this switch have zero-crossing detection?

Yes, it features tightly controlled zero-cross circuitry for switching AC loads without generating transients.

What is the maximum continuous load current for the PM1204?

The device supports a continuous load current of up to 0.5 A.

What is the maximum blocking voltage rating for the PM1204?

The switch provides a blocking voltage of up to 400 V.

What is the maximum operating frequency for the PM1204?

The unit is rated for an operating frequency between 20 Hz and 500 Hz.